Aclara Power-Line Systems Inc. Y72553-1 Manual Do Utilizador

Página de 86
66
T W A C S
®
- O R I O N
®
  f o r   U M T   P r o d u c t s   U s e r   G u i d e
Electrical Specifications
Compliance Specifications
N
OTE
ANSI C12.1-3001 is the referring standard for tests listed in tables 3.2, 3.3, and 
3.4. 
N
OTE
Per Measurement Canada, Specifications/Standards LMG-EG-07 & PS-E-09-E 
are used to verify compliance with Canadian criteria. 
Table 4.2
Compliance specifications
Device(s)
Test Title
Applicable Specification
HHTR-3 
and 
EMTR-3
EMI/RFI Emission 
conducted/radiated
 ANSI C12.1-3001 Test No. 27- “Radio 
Frequency Conducted and Radiated Emissions” 
per CFR 47 Part 15, Class A and B. (See also 
ANSI C63.4)
HHTR-3 
and 
EMTR-3
EMI/RFI Susceptibility
ANSI C12.1-3001 Test No. 26- “Effect of Radio 
Frequency Interference” 
EMTR-3
AC line surge
ANSI C12.1-3001/IEEE C62.41-1991 Test No. 
17- “Effect of High Voltage Line Surges” 
EMTR-3
Electrical fast transient
ANSI C12.1-3001 Test No. 25- “Electrical Fast 
Transient/Burst” (Testing at 100 and 400 KHz is 
required) IEC 801-4: 1988 
EMTR-3
Surge withstand 
capability FT and OSC
ANSI/IEEE C.37.90.1 - 2002
EMTR-3
High voltage isolation on 
meter chassis
ANSI C12.1-3001 Test No. 15- “Insulation”
EMTR-3
Voltage interruption test
ANSI C12.1-3001 Test No. 16- “Voltage 
Interruption”
HHTR-3 
and 
EMTR-3
Effect of electrostatic 
discharge
ANSI C12.1-3001 Test No. 28- “Effect of 
Electric Discharge (ESD)”
EMTR-3
Effect of Variation of 
Frequency
ANSI C12.1-3001. Test #6
EMTR-3
Effect of Variation of 
Voltage on the Metering 
Device
ANSI C12.1-3001. Test #5.
HHTR-3 
and 
EMTR-3
Occupied Bandwidth
200 kHz. The ORION equipment transmits at 
100 kilobits/second. The HHTR transmits at 
9600 bits per second, but uses a wider frequency 
deviation so that the occupied bandwidth is still 
in the 200 kHz range.
HHTR-3 
and 
EMTR-3
RF Output Power
FCC 15.249 compliant. IC RSS-210 A2.9; 2005 
compliant.
HHTR-3 
and 
EMTR-3
Design Frequency 
Accuracy
+/- 50 parts per million.
DRAFT