4.4 Setting the Trap Server of the EU-200BX (Optional) 
 
① 
Type <vi /mtd/etc/snmpd.conf>  
② 
When the following screen appears, type<i> to change to the insert mode.   
③ 
Type <trap2sink TRAP_SERVER_IP public>. The TRAP_SERVER_IP refers to the IP 
address of the EMS Server to where the trap messages will be sent. It is possible to 
designate multiple Trap Servers.   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 17 Trap Server Configuration 
 
[Note 1] To delete a typo in the IP address, you must FIRST EXIT the insert mode. 
This can be done by using the <ESC> key. Then point the cursor to the letter to 
delete and press the <x> key. One letter will be deleted at a time. To reenter the IP 
address, type <i> to return to the insert mode.   
 
[Note 2] If the cursor does not move using the direction keys, check if the 
emulation setting is set to VT100. If the emulation is NOT SET to VT100, the cursor 
may not move.   
 
④ 
Use the <ESC> key to exit the insert mode.