Avitec AB CSFT1922 Manual Do Utilizador

Página de 112
  
COMMAND AND ATTRIBUTE SUMMARY
 
 
© Avitec AB 
6/15/2004 
9 (96)  
The repeater can be configured to measure the antenna isolation on a certain timepoint of the day 
(configured using attributes AIE and AIT). If antenna isolation is too low (as configured with attribute 
ALA AIM), an alarm is triggered. 
For details about the antenna measurement, please refer to attribute ACT AIM in section “Miscellaneous 
Command Attributes” 
The antenna isolation is measured using the BCCH downlink and a second listener channel.  
By default, downlink chain 1 and 2 settings are used for the antenna measurements. If only one chain is 
enabled in the repeater, or if measurement should be done on other channels, this attribute can be used to 
configure the alternate channels. 
Format: 
X Y 
X is the BCCH channel, and Y is the second channel used in the measurements. 
If configured to 0, same as configured in CHA 1 and 2 is used. 
Example: 
GET AIC 
Reply: 
0 122 
means that BCCH channel used is the one used in chain 1, but the listener channel is 122. 
Example: 
SET AIC 46 51 
configures the BCCH used during measurements to 46, and listener channel to 51. 
Note!
 Antenna isolation is not measured in Fiber Optic repeaters and repeaters CSFT18922 and 
CSFT91822. 
2.4 
AIE - Antenna Isolation Measurement Enabled 
Attribute type: Read and Write 
The repeater can be configured to measure the antenna isolation on a certain timepoint of the day 
(configured using attributes AIE and AIT). If antenna isolation is too low (as configured with attribute 
ALA AIM), an alarm is triggered. 
For details about the antenna measurement, please refer to attribute ACT AIM in section “Miscellaneous 
Command Attributes” 
This attribute configures if the automatic measurement should be enabled or not. 
Format: 
X = 0 means measurement of antenna isolation is disabled and X  = 1 means measurement of antenna 
isolation is enabled. 
Example: 
GET AIE 
Reply: 
means that the repeater will measure the antenna isolation once per day. 
Example: 
SET AIE 1 
disables the measurement.  
Note!
 Antenna isolation is not measured in Fiber Optic repeaters and repeaters CSFT18922 and 
CSFT91822. 
2.5 
AIM - Antenna Isolation Measurement Status 
Attribute type: Read only