2. Clean and dry both the selected area and the face of the
transducer with a weak solvent to remove any dust,
grease or oil.
3. If the hull temperature is above 15
º
C (60
º
F), mix the
epoxy until the color is uniform. Do not proceed if the hull
temperature is below 15
º
C (60
º
F) because the cure
time will be greatly extended.
4. Apply a generous amount of epoxy to the center of the
face of the transducer (side opposite from the cable).
5. Press the transducer face onto the hull with a twisting
motion to expel all air bubbles. (If the hull is slanted, tem-
porarily secure the transducer in place with duct tape.)
The adhesive is cured in 24 hours at 21
º
C (70
º
F). The
lower the temperature the longer the cure time.
6. 
A
fter the adhesive has cured, route the cable to the
transmitter being careful not to tear the cable jacket
when passing it through the bulkhead and other parts of
the boat. To reduce electrical interference, separate the
transducer cable from other electrical wiring and sources
of interference. To prevent damage, cut the transducer
cable to the desired length.
NOTE!!!!
The working time of the epoxy is only 5 minutes. 