7.4.4.51
RB Error state
ID:
0x1011
Service: iden
Severity: major
Cause:
Equipment Malfunction
System Reaction:
RadioBlade Locked
Repair Action:
System failed to read EEPROM calibration data from the RadioBlade.
Try a different slot or replace RadioBlade.
Try a different slot or replace RadioBlade.
7.4.4.52
Logical Channel Setup error
ID:
0x1012
Service: iden
Severity: major
Cause:
Communications Protocol Error
System Reaction:
No Action Taken
Repair Action:
Ignore if occurs while 1 or more BRs are being locked or system shuts
down. Otherwise report problem to RFN.
down. Otherwise report problem to RFN.
Note: There is currently a known issue in which this alarm may appear if
many BRs are being locked at the same time.
many BRs are being locked at the same time.
7.4.4.53
Tx DSP not responding
ID:
0x1013
Service: iden
Severity: major
Cause:
Equipment Malfunction
System Reaction:
SPAM Reset
Repair Action:
Problem occurs if DSP stops transmitting data. Replace AIC.
7.4.4.54
Rx DSP not responding
ID:
0x1014
Service: iden
Severity: major
Cause:
Equipment Malfunction
System Reaction:
SPAM Reset
Repair Action:
Problem occurs if DSP stops receiving data. Replace AIC.