81 
7.4.4.51 
RB Error state 
ID:  
0x1011 
Service: iden 
Severity: major 
Cause:  
Equipment Malfunction 
System Reaction: 
RadioBlade Locked 
Repair Action: 
System failed to read EEPROM calibration data from the RadioBlade. 
Try a different slot or replace RadioBlade. 
7.4.4.52 
Logical Channel Setup error 
ID:  
0x1012 
Service: iden 
Severity: major 
Cause:  
Communications Protocol Error 
System Reaction: 
No Action Taken 
Repair Action: 
Ignore if occurs while 1 or more BRs are being locked or system shuts 
down. Otherwise report problem to RFN.  
 
Note: There is currently a known issue in which this alarm may appear if 
many BRs are being locked at the same time. 
7.4.4.53 
Tx DSP not responding 
ID:  
0x1013 
Service: iden 
Severity: major 
Cause:  
Equipment Malfunction 
System Reaction: 
SPAM Reset 
Repair Action: 
Problem occurs if DSP stops transmitting data. Replace AIC. 
7.4.4.54 
Rx DSP not responding 
ID:  
0x1014 
Service: iden 
Severity: major 
Cause:  
Equipment Malfunction 
System Reaction: 
SPAM Reset 
Repair Action: 
Problem occurs if DSP stops receiving data. Replace AIC.