IKUSI ELECTRONICA S.L. TR800CE-EMB Manual Do Utilizador

Página de 91
TM70Bi V3.2 (11/02)
1121174 L0.pdf
13
IKUSI reserves the right to change this information without prior notice.
7.3 - TROUBLESHOOTING
The transmitter and receiver have status monitoring LED’s, which help to identify irregularities.
The most common signals are contained in the tables below:
TRANSMITTER
LED
MEANS
Solid green
Transmitter transmitting normally. OPERATION mode.
Green pulses.
Transmitter ready for start-up. STAND BY mode.
Red slow flashing
Battery level low
Red fast flashing
Probably, EEPROM module is not plugged in.
Red double flashing
Transmitter cannot start up because a manoeuvre command is
present.
Solid red
Transmitter failure
RECEIVER
In OPERATION mode the 7 LED’s must be lit as has been previously described in section 4.3
Starting. If this is so, press the transmitter manoeuvre buttons and observe the response of the
output relays. If the response is normal, the problem is not related to the remote control
equipment and the installation must be checked. If any of the relays is not activated, the problem
is associated with the remote control equipment. If this happens, observe the appearance of the
LED’s:
LED
LIT
FLASHING
OFF
POWER
Power Supply OK
--
Power Supply not OK
HARDOK
Board OK
Slow: fault in the board
Fast: error in EEPROM
Fault in the board
SIGNAL
RF signal OK
RF signal detection in
SCANNING mode
The receiver is not receiving
RF signals
DATA
--
Is receiving the correct data
from a TM70
Signal received is not
correct
ID
--
ID Code OK
ID not recognised
ORDER
Any digital
manoeuvre ON
--
No digital manoeuvre ON
RELAY
STOP relays ON
--
STOP relays OFF
There are also two LEDs in the receiver (only available in LR72 electronic card) which informa
about the status of the CAN-BUS. If the CAN connection is not working, check the status of the
LEDs: