Deployment Examples
These deployment examples provide a visual illustration of various deployments, including deploying the Smart-Sync™ Synchronized
Time in a building with single floors and multiple floors. Different facility layouts and interiors may present a variety of considerations
when planning an accurate and effective deployment.
These deployment examples are to be referenced as general guidelines and it's recommended that a Smart-Sync Site Survey is
completed. The results of the survey provide a deployment guide for the installation of Smart-Sync devices at your facility.
Single floor | less than 200 clocks
General guidelines
l
Install Smart-Sync Bridge off a corridor and ideally in a central location.
l
Always install and power-on a Smart-Sync Bridge before installing Smart-Sync Clocks.
l
Start by installing Smart-Sync Clocks that are located closest to the Smart-Sync Bridge and then work outward. A Smart-Sync
Clock should always be first powered on at its designated installation location.
l
It's recommended to measure the Bluetooth signal strength at the installation location of the first clock - to verify its Bluetooth
wireless connection and communication path to the Smart-Sync Bridge.
l
If a clock fails to set its time, measure the Bluetooth signal strength at an installation location. This determines if the location has
adequate Bluetooth signal strength, resulting in no coverage gap.
Ideal deployment illustration