Xplore Technologies Corp. MC7750 Manual Do Utilizador

Página de 100
Testing
Rev 4  Sep.11
Proprietary and Confidential - Contents subject to change
77
8.
Use the down-arrow key to select 
Save setup as dfl
.
9.
Select 
Exit
.
Testing CDMA RF Receive path
Note:  This procedure segment is performed in 
To test the DUT’s receive path:
Note:  This procedure 
describes steps using the 
Agilent 8648C signal 
generator — the Rohde & 
Schwarz SML03 is shown 
for reference only.
1.
Set up the signal generator:
Note:  This example setup 
uses a 200 kHz offset from 
band center for testing 
using a continuous wave —
 you can use any appro-
priate baseband frequency 
offset (for example, 
100 kHz, 300 kHz, etc.).
If using a modulated 
signal, set the frequency to 
band center with no offset.
a.
Press the 
Frequency
 button to set the frequency to 1960.200 MHz for PCS 
band, Channel 600, or 881.720 MHz for Cellular band, Channel 384
b. Press the 
Amplitude
 button to set the amplitude to -55.0 dBm.
c.
Press the
 RF ON / OFF
 button to enable or disable the RF port of the signal 
generator.
2.
Read back the power level from the main receiver:
a.
AT!ENTERCND
 (Unlock the extended AT command set.)
b.
AT!DAFTMACT 
(Enter test mode.)
c.
AT!CHAN=600,1
(PCS band, channel 600)
or
AT!CHAN=384,0
 (Cellular band, channel 384)
d.
AT!RX=1
 (Turn on the main receiver.)
e.
AT!RXAGC?
 (Read back the power level, in dBm, from the main receiver.)
Response examples:
·
RXAGC = 0xFFFFFF33 = -77 dBm (Signal generator’s RF port is 
OFF)
·
RXAGC = 0x0021 = -60 dBm typical (Signal generator’s RF port is 
ON)