Opticon Sensors Europe BV 1989 Manual Do Utilizador

Página de 8
S
UPPLEMENT
PHL2700 
TERMINAL
/ RF-ID 
FEATURE
5
6.1.1   Electrical specifications
Main battery
rechargeable pack: Ni-MH
dry cell: Alkaline penlite
optional: other 2 x AA-size 
penlite
Main battery
Ni-MH: When having every 10
operating time
seconds on:     1 sec laser, 
0.4 sec. green LED, 0.4 sec. 
buzzer, 1 sec. RFIDtag reading,
0,2 sec. RFIDtag writing, 
operating time is: approx.
22 hours
Alkaline: When having every 
10 seconds on:      1 sec laser,
0.4 sec. green LED, 0.4 sec. 
buzzer, 1 sec. RFIDtag reading,
0,2 sec. RFIDtag writing,
operating time is: approx. 
43 hours
Different operation conditions 
affect the operating time
Use of other penlite batteries 
affect the operating time
Backup battery
Lithium (CR2032)
Backup battery 
If fully charged: 30 days backup 
operating time
time
Battery 
Low voltage indicated on the
management
terminal display.
When battery is low the 
terminal switches off 
automatically.
Charging method
Rechargeable Ni-MH pack in 
terminal via cradle
RF-ID
SUPPLEMENT
SPECIFICATIONS
6
6.1   
SPECIFICATIONS TERMINAL
6.1.5   Environmental specifications
Emission
According to EN50081, part 1
Immunity
According to EN50082, part 1
R&TTE
conform I-ETS 300-330
Additional specifications
Specifications RF-ID module 
(RF-ID tag reading)
Reading range up to 15 mm,
dependent on type of RF-ID tag.
Supported RF Tags at 13.56 MHz
Philips I-Code
Texas Instruments Tag-It
ISO 15693
Supported RF Tags at 134.2 kHz
Texas Instruments TIRIS