10. Durability 
 
10.1. Ambient Light Immunity 
Scanning performance is guaranteed when the range of illumination on a barcode surface 
is the following values. 
 
Incandescent light   : 0 ~ 4,000 lx 
Fluorescent light 
: 0 ~ 4,000 lx (excluding high-frequency lighting) 
Sunlight 
: 0 ~ 80,000 lx 
 
<Conditions> 
Barcode Test Sample 
OPTOELECTRONICS test chart 
PCS = 0.9, Resolution 0.25 mm, 9-digit Code 39, Quiet Zone 
10 mm, N/W Ratio = 1:2.5 
Distance 
100 mm from the front edge of the scanner. 
Angles 
Pitch: α = 0°, Skew: β = 15°, Tilt: γ = 0° 
Curvature 
R = 
∞ 
Power Voltage 
3.7 V 
 
* Be sure that the direct light or specular reflection from the light source does not enter 
the light receiving section of the OPN-2005. 
 
 
10.2. Vibration Strength (without packing) 
There shall be no sign of malfunction after the following vibration test. 
Vibration test: Increase the frequency of the vibration from 10 Hz to 100 Hz at an 
accelerated velocity of 19.6 m/s2 (2.0 G) for 30 minutes (60 minutes for a cycle) in the 
non-operating state. Repeat this in each X, Y and Z direction. 
 
 
10.3. Vibration Strength (in individual packing) 
There shall be no sign of malfunction after the following vibration test.
 OPN-2005
 
Specifications Manual
 
 
Vibration test: Increase the frequency of the vibration from 10Hz to 100Hz at an 
accelerated velocity of 19.6 m/s2 (2.0 G) for 30 minutes (60 minutes for a cycle) in 
individual packaged state. Repeat this in each X, Y and Z direction.