                OPN-2005
 
 
                                                                                                                                                                 Specifications Manual
  
 
 
 
 
 
 
 
6.4. Scan Area and Depth of Field 
 
Figure 3: Scan Range and Depth of Field
 
 
 
 
  
Resolution  
 
Symbology  
 PCS  
 Quiet Zone    
No. of Digits    
1.0 mm 
Code 39 
0.9 
25 mm 
0.5 mm 
Code 39 
0.9 
18 mm 
0.25 mm 
Code 39 
0.9 
10 mm 
0.15 mm 
Code 39 
0.9 
7 mm 
10 
0.127 mm 
Code 39 
0.9 
5 mm 
 
<Conditions> 
Bar Code Sample 
: Optoelectronics Test Chart, N/W ratio = 1:2.5 
Angle 
: α = 0° β = 15° γ = 0° 
Curvature 
: R = ∞