Locking system variants
The individual locking systems in the SAFE-O-TRONIC
®
access range vary in their functionality and features.
The locking systems come with PIN functionality (100 and 200), with RFID functionality (300) or with a combi-
nation of PIN and RFID functionality (400). The energy requirement of these locking systems varies and also
influences the battery life. For example, the energy requirement of a 400 model is approx. 1.4 x higher than of
a 300 model. The battery life indicated refers to an average value that was determined using the 300 model.
nation of PIN and RFID functionality (400). The energy requirement of these locking systems varies and also
influences the battery life. For example, the energy requirement of a 400 model is approx. 1.4 x higher than of
a 300 model. The battery life indicated refers to an average value that was determined using the 300 model.
Transponders
The energy requirement of the locking systems depends on the transponder type used. The DesFire tran-
sponder in the Mifare transponder range requires most energy for read and write access.
sponder in the Mifare transponder range requires most energy for read and write access.
Configuration and user behaviour
The configuration (release time, status display etc.) and the user behaviour impact on the battery life of the
locking system. Refer to the relevant sections in the guides for details on this topic.
locking system. Refer to the relevant sections in the guides for details on this topic.
Battery management
The electronic locking systems in the SAFE-O-TRONIC
®
access range are fitted with integrated battery man-
agement with an optical low-battery signal to indicate that the battery requires replacement. Refer to the rele-
vant guides for details on this topic.
vant guides for details on this topic.
Information on battery replacement
The point at which the SAFE-O-TRONIC
®
access battery pack must be replaced depends on how of-
ten the locking system was activated, or how long the battery pack has been installed, and on the am-
bient temperature in which the locking system is operated.
bient temperature in which the locking system is operated.
Due to slight, yet unavoidable, self-discharge of the batteries it may be necessary to replace the bat-
tery pack before the number of activations indicated has been reached.
tery pack before the number of activations indicated has been reached.
There is a risk of injury through improper handling of the batteries.
Only replace batteries with the door open. A function check after replacing a battery should always be
performed with the door open.
performed with the door open.
Installation and battery replacement must only be performed by trained specialists in accordance with
these operating and installation instructions.
these operating and installation instructions.
Check the time after every battery replacement and reprogram the current time where necessary.
Only use battery packs sold by Schulte-Schlagbaum.
Do not allow the battery to reach temperatures in excess of the recommended storage temperature.
Battery replacement CS300: Avoid damage to the seal ring through improper handling. Do not use
sharp objects and do not stretch the seal ring more than necessary when sliding it on.
sharp objects and do not stretch the seal ring more than necessary when sliding it on.
Ensure that the polarities are correct when inserting the batteries.
Always replace discharged batteries with new batteries.
Battery packs may not be charged.
Disposal
Recycle defective or used battery packs according to European Directive 2006/66/EG.
Observe local regulations concerning the disposal of batteries.
Observe local regulations concerning the disposal of batteries.