Radwin Ltd. AMWL1240 Manual Do Utilizador

Página de 98
WinLink 1000 Installation and Operation Manual 
Chapter 
 
2  Installation and Setup 
 
Installation and Setup 
2-5 
 
Prior to connecting cables to the ODU, the protective earth terminal 
(screw) of the ODU must be connected to an external protective ground 
conductor or to a grounded mast. 
Only a qualified person using the proper safety equipment should 
climb the antenna mast. Only trained professional installers should be 
used when installing or dismantling ODUs and masts. 
 
Î
 
To mount the ODU: 
1.  Verify that the ODU mounting brackets are properly grounded. 
2.  Attach the ODU unit to the mast. Refer to 
Appendix B
 for the ODU 
mounting instructions.  
3.  Connect the ground cable to the chassis point on the ODU. 
4.  Attach the ODU cable to the RJ-45 connector. Refer to 
Appendix A
 
for the connector pinout. 
5.  Secure the cables to the mast or brackets using provided UV-rated 
cable ties. 
6.  Repeat the procedure at the remote site. 
 
Do not tightly secure the ODU to its mounting brackets, until the 
alignment process of the antenna is complete. 
When installing the ODU, it is important to check that there are no 
direct obstructions in front of the ODU or interference from man-made 
obstacles. 
 
Connecting the ODU to the IDU 
The ODU cable conducts all the user traffic between the IDU and the 
ODU. The ODU cable also provides -48 VDC supply to the ODU. The 
maximum length for one leg of the ODU cable is 100m (328 ft) in 
accordance with10/100BaseT standards. 
ODU cable is supplied pre-assembled with RJ-45 connectors, at the 
length specified when ordering. If the ODU cable was not ordered, use 
Cat. 5e shielded cable, the wiring specifications are given in 
Appendix A
1.  Route the cable from the ODU location into the building, leaving 
some spare. Secure the cable along its path. 
Warning 
Note