26
Enter Setup 
Scanner Configuration 
SmartScan Manual
4.3 CODE 25 PARAMETERS 
4.3.1 INDUSTRIAL 25 
Serial Command
0080
Serial Command 
0081
 
     <Enable> 
 
Disable 
START / STOP PATTERN SELECTION 
Serial Command
0130
Serial Command 
0131
 
  <Industrial 25> 
 
 Interleaved 25 
Serial Command
0132
 
     Matrix 25 
 
  
CHECKSUM VERIFICATION 
Serial Command
0139
Serial Command 
0140
 
      Enable 
 
 <Disable> 
CHECKSUM TRANSMISSION 
Serial Command
0141
Serial Command 
0142
 
     <Enable> 
 
 Disable 
CODE LENGTH QUALIFICATION 
1) Read the label to enable either Max. /Min. length qualification or fixed length qualification. 
2) Read the labels for Max. /Min or fixed length separately. 
3) Read the “
Decimal Value
” label on page 57 for the desired inter-character delay (millisecond).   
4) Read the “Validate” label on the same page to complete this setting. 
Serial Command
0208
 
Enable Max./Min. Length …