Version 1.1
How to reset the coupler
Resetting the coupler may be useful to set the parameters (speed, disable mode, protocol
settings, keys ) to the defaults values. All  these values are stored in coupler’s internal
EEPROM
Software reset
It is possible to reset the coupler’s EEPROM by sending 2 commands thanks to the SET
STATUS command.
Command = $80,$F4,$80,$3E,$01 - Data = $00
Command = $80,$F4,$80,$7E,$01 - Data = $00
Then the coupler has the default setting : 9600 bds, defaults protocols....