ViVOtech Inc. VPS500A Manual Do Utilizador

Página de 15
ViVOpay OEM S500 Technical Reference 
Document: 740‐0005‐00 Rev. 1.0 
10 
 
Proprietary & Confidential 
 
Appendices 
 
Appendix A ‐ Performance Specifications 
 
Electrical 
 
DC Input Voltage (at reader) 
5VDC +/‐ 10%; 50 mV P‐P ripple 
DC Input Current (at reader) 
250 mA. (nominal) (see Note 1) 
Reader Power Up Time 
Less than 1 second after power applied 
Note 1:  Does not include Strip Drive power requirements.
 
 
 
Environmental 
 
Operating Temperature 
‐25° C to 70° C (‐13° F to 158° F) 
Storage Temperature 
‐40° C to 85° C (‐40° F to 185° F) 
Cold and Heat Shock 
‐40° C to 85° C (‐40° F to 185° F) within 2 hrs. 
Operating Humidity 
10% to 90% non‐condensing 
Operating Environment 
Indoor and sealed outdoor use only 
 
 
Operational 
 
Transmitter Frequency 
13.56 MHz +/‐ 0.01% 
Transmitter Modulation 
ISO 14443‐2 Type A 
Rise/Fall Time:  2‐3 μsec. Rise, < 1 μsec fall 
ISO 14443‐2 Type B 
Rise/Fall Time:  < 2 μsec. each; 8% ‐ 14% ASK 
Receiver Subcarrier Frequency 
847.5 KHz 
Receiver Subcarrier Data 
ISO 14443‐2 Type A:  Modified Manchester 
ISO 14443‐2 Type B:  NRZ‐L, BPSK 
Typical Read Range 
5‐7 cm.