8.1  Mobile PTP Link Step-by-Step
 
Configuration  
In order to build a Mobile PTP link, 2 MCUs are required. One MCU acts as a VC, while 
the other as a Node. 
 
1.  Connect antennas to RF1 and RF2 connectors, and power up the MCU.  
 
 
CAUTION – Powering up an MCU unit without connecting the antennas 
can cause unrepairable damage to it.  
 
2.  Connect the MCU to a PC using a standard Ethernet Cat 5 cable. 
3.  Set static IP in the 192.168.131.xxx subnet. (for more information see MC-
EMA P2P User Manual). 
4.  Using the MC-EMA: connect to the MCU (VC or Node, by default. The MCUs 
are shipped with a Mobile PTP SW and are set as a VC). From the MC-EMA, 
connect to screen choose the unit and click on the “Connect” button. 
 
Figure 8: MC-EMA-PTP connect to screen 
 
5.  From the MC-EMA main menu (on the left side) choose the  configuration 
screen and set the MCU to VC (if needed) 
by choosing the VC “radio button” 
than  click on the “Set Mode” button  – the unit will reboot 
6.  Change the frequency to the required frequency 
and click on the “Set 
Frequency” button – the unit will reboot 
7.  Set the profile as required (RF bandwidth, bitrate and ratio) 
click on the “Set” 
button 
“- the unit will reboot 
8.  Repeat stages 1-4 with the 2
nd
 unit.  
9.  Go to configuration screen and set the MCU to Node (if needed) 
– the unit will 
reboot. 
10. Repeat stages 6-7 with the 2
nd
 unit.