Hewlett Packard Enterprise Company AP175SDR Manual Do Utilizador
Aruba AP-175 Outdoor Access Point
| Installation Guide
23
Figure 19 Attaching the AP to the Mounting Bracket
Grounding the AP-175
The grounding must be completed before powering up the AP-175. The resistance of grounding wire should
be less than 5 ohm and the grounding cable’s cross-section area should be no less than 6 mm.The grounding
hole is at the right side of the AP-175.
be less than 5 ohm and the grounding cable’s cross-section area should be no less than 6 mm.The grounding
hole is at the right side of the AP-175.
Figure 20 Grounding the AP-175
1. Peel the cover of one end of the grounding cable (green or yellow and green grounding cable with 6 mm
cross-section area) and place the bare grounding cable into the copper lug, and press firmly with the
crimping pliers.
crimping pliers.
2. Fasten the copper lug to the grounding hole on the AP-175 with the M4 x12 bolt and external-tooth
washer.
Front
Front
AP175_08