Controlled Electronic Management Systems Ltd INFOPROX Manual Do Utilizador
InfoProx Hardware Installation
InfoProx Entry
4. InfoProx Hardware Installation
The enclosure is designed to mount directly onto a standard UK or European (French)
electrical containment box (USA installations require an adapter plate), and standard
conduit and fittings can be used. A clear polycarbonate screen covers the LCD for
protection.
electrical containment box (USA installations require an adapter plate), and standard
conduit and fittings can be used. A clear polycarbonate screen covers the LCD for
protection.
Cables are pulled through the conduit and terminated in the containment box. The
following cables are required:
following cables are required:
Cable
Connector
2-pair (Belden 8723) cable for power and data
4-pin socket (J3)
5-pair (max) cable for inputs and output
10-pin socket (J2)
2-pair (Belden 8723) cable to exit reader
1 RS485 cable for female RJ45 connector
4-pin socket (J3)
4-pin socket (J5)
The various cables use Phoenix Contact connectors for the unit’s inputs and outputs.
The cables are secured into screw terminals. A flat blade screwdriver of 1/8” or less is
recommended.
The cables are secured into screw terminals. A flat blade screwdriver of 1/8” or less is
recommended.
The Phoenix Contact terminals used for the power and
communication connections can accommodate two leads
fitted into one terminal.
communication connections can accommodate two leads
fitted into one terminal.
Two stainless steel tamper-resistant mounting screws are supplied and are concealed
behind specially molded covers when installation is complete.
behind specially molded covers when installation is complete.
14