Controlled Electronic Management Systems Ltd INFOPROX Manual Do Utilizador

Página de 79
InfoProx Hardware Installation 
 
InfoProx Entry   
4.  InfoProx Hardware Installation 
The enclosure is designed to mount directly onto a standard UK or European (French) 
electrical containment box (USA installations require an adapter plate), and standard 
conduit and fittings can be used. A clear polycarbonate screen covers the LCD for 
protection. 
Cables are pulled through the conduit and terminated in the containment box. The 
following cables are required: 
Cable 
Connector 
2-pair (Belden 8723) cable for power and data 
4-pin socket  (J3) 
5-pair (max) cable for inputs and output 
10-pin socket  (J2) 
2-pair (Belden 8723) cable to exit reader 
1 RS485 cable for female RJ45 connector  
4-pin socket  (J3) 
4-pin socket  (J5) 
The various cables use Phoenix Contact connectors for the unit’s inputs and outputs
The cables are secured into screw terminals. A flat blade screwdriver of 1/8” or less is 
recommended. 
 
The Phoenix Contact terminals used for the power and 
communication connections can accommodate two leads 
fitted into one terminal. 
Two stainless steel tamper-resistant mounting screws are supplied and are concealed 
behind specially molded covers when installation is complete. 
14  
Software 
House