Controlled Electronic Management Systems Ltd INFOPROX Manual Do Utilizador

Página de 79
Configuring the Door Control Unit 
 
InfoProx Entry   
Configuring the reader 
Now you are ready to configure your reader. Before you start, you need to be 
aware that the Configuration mode screens are set to automatically change to the 
next screen after five seconds. If this happens and your data has not been 
entered, either return to the screen at the end of the automatic sequence or press 
to scroll through the rest of the screens and return to the Administration menu.  
Press 3 to restart the configuration mode sequence. 
 
Accessing the configuration setup 
1. 
To access configuration setup, enter the key sequence (# 0 
Ù). 
2. 
Enter the password when prompted. 
The Administration menu prompt appears. 
 
0-Del,1-Add 
2-Find,3-Config 
3. 
Press 3 to access the Configuration Setup mode to access the 
operational settings of the reader to be configured. 
The Configuration Setup prompt appears 
 
Config Time ? 
0-Yes, Other-No  
as the first screen in the configuration mode setup screens: Config Time; 
Config TZ Start; Conf TZ End; Config TZ Type; Config I/Ps; Set Drsk; 
Set Drclose; Set GIN; Set Scode 
 
After you enter data on the configuration mode screen, the next screen in the 
sequence usually appears automatically. However, confirmation by entering an 
Ù 
will be required on some screens. 
To skip or page through setup screens, press #.  This will return you to the 
Administration screen, where you can complete another task, reenter the 
Configuration Setup modes, or exit. 
28  
Software 
House