Figure 8: System - AN-100UX Front Panel
3.1.1 Mounting
The indoor equipment can be freestanding on a flat surface or in a 19-inch rack.
3.1.2 Power Supply
The AN-100U and AN-100UX (high power) equipment have different power supply
features. Read the following section carefully to determine the correct power
requirements and options. All models feature double pole/neutral fusing. Refer to the
Installation Guidelines manual for additional information about DC power wiring.
features. Read the following section carefully to determine the correct power
requirements and options. All models feature double pole/neutral fusing. Refer to the
Installation Guidelines manual for additional information about DC power wiring.
Warning to service personnel:
Caution for all AC and DC models
– Double Pole/Neutral fusing.
AN-100U
Power supply options include single or dual AC or DC supplies, or a combination of AC
and DC power supplies. Cables are included with both AC and DC power supplies.
and DC power supplies. Cables are included with both AC and DC power supplies.
Table 7 - IDU Installation - RedMAX AN-100U Power Specifications
Voltage range
[V]
Tolerance
[%]
Power
consumption
max. [W]
Max.
Current
[A]
Inrush
current
1
[A]
AC Input
2
100-240 VAC
10%
75
2
35
DC Input
2
24-60 VDC
20%
75
6
40
1. Typical Inrush current is less then 500 us. DC: measured, AC: P/S manufacturers data.
2. Auto-sensing.