Table 26: Specifications - Indoor Wireless Subscriber Modem
Power Requirements:
Auto-sensing 110/220/240 VAC 50/60 Hz, 10.5 W
Compliance:
EMC: EN 301 489-1, EN 301 489-4, EN 55022/CISPR 22
RF: EN 301 021, EN 301 753, IC RSS-192, FCC Part 90/15
Safety: IEC 60950-1, EN 60950-1, UL 60950-1
Operating Temperature:
-5 C to 40 C
Antenna:
Integrated flat panel (10.44 dBi)
Dimensions (L x W x H):
8.9 x 7.0 x 20.6 cm (3.5 x 2.74 x 8.12 in)
3
Weight:
0.45 Kg (1.0 lb)
3
1
Frequency range dependant on installed radio option, license, and regulatory domain.
2
Actual Ethernet data throughput is dependent on channel size, protocols, packet size, burst
rate, transmission latency, and link distance.
3
Based on a subscriber unit with integrated vertical antenna and stand attached
5.2
Subscriber Log Messages
Table 27: Troubleshooting - Event Log Messages
Log Message
Description
Add classifier [CID: XXXX,
Idx: nn]
A classifier with the following CID has been added.
Broadcast Opportunity
Corrupted
Opportunities have been received for initial ranging, but the
opportunity is not appropriate (i.e. too short) for this subscriber.
Broadcast Ranging
Opportunity Received
This message indicates that the base station has provided an
opportunity for subscriber registration.
Broadcast Ranging
Opportunity Timeout
This message indicates that the base station has not provided
an opportunity for new subscriber registration within the last 10
seconds.
seconds.
Classifier deleted [Idx: nn]
The specified classifier has been deleted.
Classifiers deleted for SF
with CID XXXX
All classifiers have been cleared for the specified service flow.
DCD Receiving Timeout
The subscriber has not received downlink channel descriptors
for five consecutive opportunities. The subscriber will now
restart the ranging process in an attempt to re-establish
wireless synchronization.
restart the ranging process in an attempt to re-establish
wireless synchronization.
Deregistration DREG-CMD,
action code: nn
The subscriber has de-registered.
Deregistration DREG-CMD,
action code: nn
base station has requested that subscriber should deregister.
DHCP Error
There has been an error in obtaining a DHCP lease
Downlink Burst Profile
Adjusted [BP: nn]
Downlink modulation rate has been adjusted by the base
station.
Downlink Burst Profile
Change Attempt [BP: nn]
A request to change the downlink modulation rate has been
made based on locally configured CINR thresholds.