Woosim System Inc. PORTI-WC40 Manual Do Utilizador

Página de 25
 
http://www.woosim.com
 
15
2
2
.
.
5
5
.
.
 
 
S
S
e
e
t
t
 
 
o
o
p
p
e
e
r
r
a
a
t
t
i
i
o
o
n
n
 
 
m
m
o
o
d
d
e
e
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1.  Press the MODE Button until the 
Error Lamp
 twinkles 5 times. 
2.  Change the mode and option using the MODE Button according to the MODE 
(Table1). 
MODE button : use for changing OPTION status. (
Error Lamp
FEED button : use for changing MODE status.      (
Power Lamp
Ex) The defaults of the printer are :   
UART/ 9600 bps/ 8 data bit / No parity/ Density Low 
            If a user wants to modify the defaults with : 
Bluetooth / 38400 bps / 7 data bit/ Even parity/ Density high 
 
Press MODE Button until 
Error Lamp
 twinkles 5 times and release the 
button. 
             
→ You will see the 
Power Lamp
 twinkles once and the 
Error Lamp
 
twinkles once. 
             
→ Press the MODE Button twice and the 
Error Lamp
 twinkles three times. 
                    (The interface mode has set to Bluetooth mode.) 
Press FEED button one time, 
Power Lamp
 twinkles twice and 
Error Lamp
   
twinkles once. 
             
→ Press the MODE Button twice, and the 
Error Lamp
 twinkles three times. 
  (The baud rate has set to 38,400 bps) 
Press FEED Button once, 
Power Lamp
 twinkles three times and 
Error Lamp
 
twinkles twice. 
             
→ Press MODE Button one time, 
Error Lamp
 twinkles one time. 
          (The Data Bit has set to 7 Data bit) 
Press FEED Button one time, 
Power Lamp
 twinkles four times and 
Error Lamp
 
twinkles once. 
             
→ Press MODE Button one time, 
Error Lamp
 twinkles two times. 
          (The Parity bit has set to Odd parity bit)