Woosim System Inc. PORTI-WC40 Manual Do Utilizador
http://www.woosim.com
15
2
2
.
.
5
5
.
.
S
S
e
e
t
t
o
o
p
p
e
e
r
r
a
a
t
t
i
i
o
o
n
n
m
m
o
o
d
d
e
e
1. Press the MODE Button until the
Error Lamp
twinkles 5 times.
2. Change the mode and option using the MODE Button according to the MODE
(Table1).
z MODE button : use for changing OPTION status. (
Error Lamp
)
z FEED button : use for changing MODE status. (
Power Lamp
)
Ex) The defaults of the printer are :
UART/ 9600 bps/ 8 data bit / No parity/ Density Low
If a user wants to modify the defaults with :
Bluetooth / 38400 bps / 7 data bit/ Even parity/ Density high
X
Press MODE Button until
Error Lamp
twinkles 5 times and release the
button.
→ You will see the
Power Lamp
twinkles once and the
Error Lamp
twinkles once.
→ Press the MODE Button twice and the
Error Lamp
twinkles three times.
(The interface mode has set to Bluetooth mode.)
X
Press FEED button one time,
Power Lamp
twinkles twice and
Error Lamp
twinkles once.
→ Press the MODE Button twice, and the
Error Lamp
twinkles three times.
(The baud rate has set to 38,400 bps)
X
Press FEED Button once,
Power Lamp
twinkles three times and
Error Lamp
twinkles twice.
→ Press MODE Button one time,
Error Lamp
twinkles one time.
(The Data Bit has set to 7 Data bit)
X
Press FEED Button one time,
Power Lamp
twinkles four times and
Error Lamp
twinkles once.
→ Press MODE Button one time,
Error Lamp
twinkles two times.
(The Parity bit has set to Odd parity bit)