Leviton Manufacturing Co. Inc. RZC0P Manual Do Utilizador

Página de 3
Plug-In Serial Interface Module
Cat. No. RZCØP
Rated: 120VAC, 60Hz
INStallatIoN INStRuCtIoNS
DI-000-RZC0P-00A-X3
 INtRoDuCtIoN
Leviton’s Vizia
TM
 RF components are designed 
to communicate with each other via Radio 
Frequency (RF) to provide remote control 
of your lighting. Using RF technology allows 
Leviton to provide the greatest signal integrity 
possible. Each module in Leviton’s Vizia
TM
 
RF component line is a Z-Wave
TM
 enabled 
device. In a Z-Wave
TM
 network, each device is 
designed to act as a router. These routers will 
re-transmit the RF signal from one device to 
another until the intended device is reached. 
This ensures that the signal is received by its 
intended device by routing the signal around 
obstacles and radio dead spots. The Plug-in 
Serial Interface Module is compatible with any 
Z-Wave™ enabled network, regardless of the 
manufacturer and can also be used with other 
devices displaying the Z-Wave™ logo. 
CautIoN:
Remember to exercise good common sense 
when using the Timer features of your remote, 
especially when scheduling unattended 
devices. There can be some unexpected 
consequences if not used with care. For 
example, an empty coffee pot can be remotely 
turned on. If that should happen, your coffee 
pot could be damaged from overheating. If an 
electric heater is turned on by remote control 
while clothing is draped over it, a fire could 
result.
Including Plug-In Serial 
Interface Module into Z-Wave
tM
 
Network:
 
Step 3
attaching Plug-In Serial 
Interface Module to Wall 
Receptacle:
 
Step 2
attaching Serial-RS232 Cable 
or HaI Cable to Plug-In Serial 
Interface Module:
 
Step 1
NotE: In order to use your Vizia
TM
 Plug-In Serial 
Interface Module in a Z-Wave
TM
 network, it must 
be Included into the network using a Primary 
Programmer/Remote, such as Leviton’s Cat. 
No., RZCPG. Before Including your module, 
please refer to the Primary Programmer/Remote 
instruction sheet for complete information. Refer 
to Step 3 for further details.
NotE: Use check boxes           when Steps 
are completed.
INStallING YouR INtERFaCE MoDulE
RS232 cable
to CPU
HAI cable
to HAI controller
RS232 cable to 
Interface Module
HAI cable to 
Interface Module
OR
WaRNINGS aND CautIoNS:
•  To be installed and/or used in accordance with appropriate electrical codes and regulations.
•  If you are unsure about any part of these instructions, consult a qualified electrician.
WaRNINGS aND CautIoNS:
•  Save this instruction sheet. It contains important technical data along with testing 
and troubleshooting information which will be useful after installation is complete.
•  RS232 - ASCII
•  Scene capable 
•   Two way communication
•   RF reliability 
•   Ease of installation – No new wiring
•   Compatible with other Z-Wave™ enabled 
devices
NotE: This product requires the use of 
third party software to function, along with a 
relatively high level of programming skill. 
 FEatuRES
 
Step 3 cont’d
Programming  
Button
ON
ON
ON
ON
OFF
OFF
OFF
OFF
Programmer/Remote
Cat. No. RZCPG
Center Button
Menu Button
Compatible with
enabled products!
TM
NotES:
•  If using a non-Leviton Programmer/Remote, 
refer to the Programmer/Remote instruction 
sheet.
•  Plug-In Serial Interface Modules included into 
a Z-Wave
TM
 network must be updated after you 
have included all other devices.
a)  If using a Leviton Z-Wave
TM
 Programmer/
Remote, Cat. No. RZCPG, press the Menu 
button and scroll down to System Setup. Press 
the center button to select System Setup Menu. 
Press the center button to select Network. 
Press the center button to <Include Node>.
B)  If using RZCPG Programmer/Remote, you will 
be prompted to prepare device for inclusion. To 
do this you must put the Plug-In Serial Interface 
Module into programming mode. 
C)  To access Program mode, press and hold 
programming button until the LED turns Amber. 
You are now in Programming mode.
 
NotE: If the LED on the Plug-In Serial 
Interface Module turns solid Red while 
including, there has been a communication 
error.
D)  While standing close to the Plug-In Serial 
Interface Module (approximately 2-5 ft.), press 
the center button on the Programmer/Remote 
to <Include> device in the network. NotE: 
Only one device may be included at any time.
E)  The Primary Programmer/Remote will 
assign a Home ID, Node ID, and Name for 
this device.
 
NotE: This information will be stored in the 
Programmer/Remote to be used for future 
reference.
 
NotE: You may name or edit the node of 
this device at this time.
F)  the Plug-In Serial Interface Module is 
now installed in the network.
G)  After all devices are included into the 
network, the Plug-In Serial Interface 
Module must be updated to allow proper 
network function. To update Plug-In Serial 
Interface Module proceed as follows:
 
•   If using a non-Leviton Programmer/
Remote, refer to the Programmer/
Remote instruction sheet for updating 
Plug-In Serial Interface Module.
 
•   If using Leviton Z-Wave
TM
 Programmer/
Remote, Cat. No. RZCPG, press the 
Menu button and scroll down to System 
Setup. Press the center button to select 
  System Setup Menu. Press the center 
button to select Network. Press the 
center button to select Update "cntrl". 
When prompted, press button on the 
Plug-In Serial Interface Module.
 
•   Wait until the RZCPG Programmer/
Remote confirms completion. Update 
is done.
NotE: If the Plug-In Serial Interface Module 
has been successfully Included in the 
network and the user tries to Include it again 
without first excluding it from the network, the 
controller will retain the first node ID it had 
received and ignore the second.
•  Attach RS232 cable to Plug-
In Serial Interface Module 
and CPU.
  oR
  Attach HAI cable to Plug-In 
Serial Interface Module and 
HAI controller.
•  Plug the Plug-in 
Serial Interface 
Module into wall 
receptacle. Verify 
that receptacle is 
live. If controlled 
by a wall switch, 
the switch must 
be kept oN at all 
times.