Itron SGRCWZ Manual Do Utilizador

Página de 61
GridRouter™ User Guide 
 
 
 
 
11 
 
3.3  Ports & Switches 
 
 
Figure 3-2: Inside the 
Basic 
GridRouter
 
NOTE: Actual Configuration may vary  
 
3.3.1  Power 
The GridRouter power board is available in either an AC or DC configuration. For the AC configuration 
the power plug should be connected to a 120VAC supply. The DC configuration should be connected to a 
9-30VDC supply capable of at least 20 watts. The power switch is ON when pushed to the left, OFF when 
pushed to the right. When first powered up the status LED will be solid orange for roughly 60 seconds 
before it starts to blink. While the status LED is blinking orange during low-level boot up, holding down the 
reset button for 6 seconds will result in a factory reset.  The status LED will alternate between green and 
red to designate this event.  While the status LED is blinking green during normal operation, holding down 
the reset button will turn the status LED red and result in a clean reboot of the GridRouter if held for more 
than 6 seconds.   
 
To cleanly power off the GridRouter, the reset button should be held until the status LED stops blinking. 
Directly after the status LED turns solid orange again, the device should be powered off.  
 
Failure to cleanly power off the GridRouter can result in data loss and possible corruption on the 
system.
 
Ethernet 
Serial Port 0 
Serial Port 1 
Reset Button 
Power Plug 
 
Battery LED 
 
LED Array 
 
Power Switch 
Mounting Bracket 
 
Formatted: Font: Bold
Formatted: Normal