LSM-20 Instructions 
P/D 112609
LSM-20
by EVOLVE GUEST CONTROLS
2
The LSM-20 supports the Association command.
The LSM-20 can be set to control other Evolve devices. You can turn on and off, and even dim other Evolve devices once they are “associ-
ated
” into either of 2 groups with the LSM-20. 
A NOTE AbOUT DIMMERS IN A GROUP: If you combine Evolve enabled dimmers and other types of Evolve devices in a group, place a Evolve 
enabled dimmer into the empty group first to ensure that the dimming operates correctly. 
Each group is turned on or off (or dimmed by tapping or holding) the switch a differing amount of times.
If you associate a Evolve device into Group 2, you can turn that device on and off by tapping the switch on or off twice. You can brighten 
or dim devices by tapping the switch on or off once and then holding the switch down. The load attached to the LSM-20 is not affected.
If you associate a Evolve device into Group 3, you can turn that device on and off by tapping the switch on or off three times. You can brighten 
or dim devices by tapping the switch on or off twice and then hold the top or bottom of the switch down. The load attached to the LSM-20 
is not affected.
You can associate up to 5 Evolve devices into each of these groups.
For instructions on how to associate a Evolve device into one of these groups, refer to your wireless controller instructions. (If you are using 
the IR-100 controller, refer to the Setup Menu, Association section).
Configuration
The LSM-20 supports the Configuration command.
The LSM-20 can be configured to operate slightly differently than how it works when you first install it. Using the Configuration command 
you can configure the following: 
You can use a IR-100 to send Configuration commands. (Refer to the Setup Menu, Configuration section)
Set ignore Start Level Bit When transmitting dim commands
The LSM-20 can send Dim commands to Evolve enabled dimmers. The Dim command has a start level embedded in it. A dimmer receiv-
ing this command will start dimming from that start level if this bit is set to 0. If the bit is set to 1, the dimmer will ignore the start level 
and instead start dimming from its current level.
• Parameter No: 1
• Length: 1 Byte
• Valid Values = 0 or 1 (default 1)
 night Light
The LED on the LSM-20 will by default, turn ON when the load attached is turned ON. To make the LED turn ON when the load attached 
is turned OFF instead, set parameter 3 to a value of 1.
• Parameter No: 3
• Length: 1 Byte
• Valid Values = 0 or 1 (default 0)
 invert Switch
To change the top of the switch to OFF and the bottom of the switch ON , set parameter 4 to 1.
• Parameter No: 4
• Length: 1 Byte
• Valid Values = 0 or 1 (default 0)
enable Shade control Group 2
The LSM-20 can control shade control devices via its group 2 if this configuration parameter is set to 1.
•  Parameter 14
•  Length: 1 Byte
•  Valid Values: 0 or 1 (default 0)
Enable Shade Control Group 3