SAM Electronics GmbH NG3028X25KW Manual Do Utilizador

Página de 144
ED 3038 G 232 / 01 (2002-06) 
Operating Instructions
18  List of Alarms
b_r1se62.fm / 21.06.02
119
RADARPILOT / CHARTRADAR
18  
List of Alarm
s
18
List of Alarms
Subjects of this Section: 
The meaning of the individual alarm indications possible reme-
dies
Special features in the case of acknowledgement
Possible remedies
The sounding of an acoustic signal is defined by the following symbols:
 
The acoustic signal is sounded regardless of how the BUZZER function is set in the USER
SETTINGS menu; se
.
 
The acoustic signal is sounded only if the BUZZER function is switched on in the USER
SETTINGS menu.
Whether an acoustic signal is sounded depends on the factors described.
If no symbol is stated, the alarm appears without an acoustic signal.
AZ OVERFLOW 
The number of targets which can be tracked in the acquisition/guard zone is exceeded.
Remedy: Check the acquisition/guard zone; delete targets.
CHART SERVER OFFLINE
The CHARTPILOT from which the chart data are taken is no longer sending any data. Therefore,
chart data are no longer available.
Remedy: Check the CHARTPILOT or switch to Radar Display Mode.
DANGEROUS TGT yy.yNM zzz° (yy.y=distance zzz=true bearing)
The tracked target situated at the displayed distance and bearing has become a dangerous target,
because the CPA and TCPA values have become smaller than the limits that were set for them.
ECDIS APPROACHING WAYPOINT
The ECDIS has detected that the next Wheel Over Point will be reached soon. Details are displayed
on the CHARTPILOT. For explanations, see the Operating Instructions of the CHARTPILOT.
ECDIS CHECK LEG
The ECDIS has detected that the existing track segment of the System Track is touching a poten-
tially dangerous region or object. For explanations, see the Operating Instructions of the CHART-
PILOT.
 1)
1)  
This alarm should be acknowledged on the CHARTPILOT after the nautical situation has been checked there with the aid of the Electronic
Chart.