TROUBLESHOOTING
NOTE: The Steam Genie FOB will not operate the generator
without an eTempo or eTempo/Plus control
I cannot control my steam generator with my Steam Genie:
____________________________________________________________________
Is the light twinkling on the
Steam Genie FOB
when the button is
pressed?
If not, replace the batteries in the
Steam Genie FOB
.
If the light still does not twinkle, contact technical service.
____________________________________________________________________
Are you within range of the
STEAM GENIE INTERFACE MODULE
?
Go closer to the steam generator and see if that works.
If the range has diminished then the
Steam Genie
FOB battery
may be getting weak.
For new installations it my be necessary to change the location of
the Steam Genie Interface Module to improve the range. Contact
Mr.Steam technical service for an optional 60 foot cable, part number
103978-60.
____________________________________________________________________
Go to the
Steam Genie Interface Module
.
Are any of the
Steam Genie Interface Module
indicator lights on?
If not check the connection to the steam generator. Unplug and
re-plug the Steam Genie Interface Module from the steam generator.
Verify the steam generator is receiving the correct voltage.
____________________________________________________________________
Press the TOGGLE STEAM button on the
STEAM GENIE INTERFACE
MODULE
and verify that it can control the steam generator. If no
lights are on or you cannot manually control the steam generator,
contact technical service.
____________________________________________________________________
Press the ON/OFF button on the
Steam Genie FOB
. While the
Steam
Genie
FOB is twinkling, do you see the yellow RF activity
light flashing on the
STEAM GENIE INTERFACE MODULE
?
If yes, then the address of the
Steam Genie FOB
and the
STEAM
GENIE INTERFACE MODULE
may not match. Enter pairing mode by
pressing the TOGGLE STEAM button on the
Steam Genie Interface
Module
until the blue light comes on. While the blue light on the
Steam Genie Interface Module
is on, press and hold the
ON/OFF
button for 2 second until the LED flashes. Exit pairing mode and
test the
Steam Genie FOB
.
PUR 100449 6/10
mr
.
steam
®
Sussman-Automatic Corp
®
info@mrsteam.com
www.mrsteam.com
43-20 34th Street
Long Island City, NY 11101
TEL
: 1 800 76 STEAM
FAX
: 718 472 3256
9410 S. La Cienega Blvd.
Inglewood CA 90301
TEL
: 1 800 72 STEAM
FAX
: 310 216 2944
STEAM GENIE BATTERY REPLACEMENT:
Your Steam Genie is equipped with a factory installed battery.
A replacement disk battery #CR2032 is available at most
local drug stores.
TO REPLACE THE BATTERY:
1. Unscrew the 2 Philips head screws on the Steam Genie FOB case
2. Pry open the hinged case.
3. Carefully lift out the circuit board.
4. Slide out the old battery.
5. Slide in a new battery making sure that the + side
is facing outwards (away from the circuit board).
6. Replace the circuit board in the case. Be sure the button
is facing the right way or else the case will not close.
7. Snap the case closed.
8. Test the remote.
9. Replace the 2 screws.
NOTE: The Steam Genie FOB will remember its address
when the battery is removed.
_______________________________________________________
Case
Battery
Circuit Board
LIST OF REPLACEMENT PARTS
________________________________________________
DESCRIPTION
PART NUMBER
________________________________________________
Steam Genie FOB
104058
Steam Genie Interface Module
104059
5
foot Interface Cable
104060
60
foot Interface Cable
103978-60
FCC ID: KSK-104058
FCC ID: KSK-104059
Mr.Steam: Steam Genie
This equipment has been tested and found to comply with the limits for a Class B digital device, pur-
suant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. Operation is subject to the following two conditions:
1) This device may not cause harmful interface, and
2) This device must accept any interface received, including
interface that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible
for compliance could void the user's authority to operate the equipment.