Digi International Inc XB3C1 Manual Do Utilizador

Página de 146
AT commands
I/O settings commands
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
104
Description
3
Digital input
4
Digital output, default low
5
Digital output, default high
Default
0
D3 (DIO3/AD3)
Sets or displays the DIO3/AD3 configuration (pin 17).
Parameter range
0 - 5
Parameter
Description
0
Disabled
1
SPI_SSEL
2
Analog input
3
Digital input
4
Digital output, default low
5
Digital output, default high
Default
0
D4 (DIO4)
Sets or displays the DIO4 configuration (pin 11).
Parameter range
0, 1, 3 - 5
Parameter
Description
0
Disabled
1
SPI_MOSI
2
N/A
3
Digital input
4
Digital output, default low
5
Digital output, default high