Digi International Inc XBEEPRO2 Manual Do Utilizador

Página de 155
XBee®/XBee‐PRO® ZB RF Modules 
© 2011 Digi International, Inc.
     131
NJ
Node Join Time. Set/Read the time that a Coordinator/Router allows nodes to join. 
This value can be changed at run time without requiring a Coordinator or Router to 
restart. The time starts once the Coordinator or Router has started. The timer is reset 
on power-cycle or when NJ changes.  
For an end device to enable rejoining, NJ should be set less than 0xFF on the device 
that will join. If NJ < 0xFF, the device assumes the network is not allowing joining and 
first tries to join a network using rejoining. If multiple rejoining attempts fail, or if 
NJ=0xFF, the device will attempt to join using association.
Note: Setting the NJ command will not cause the radio to broadcast the new value of 
NJ out to the network via a Mgmt_Permit_Joining_req; this value is transmitted by 
setting CB=2.  See the command description for CB for more information.
CRE
0 - 0xFF  
[x 1 sec]
 0xFF 
(always allows joining)
JV
Channel Verification. Set/Read the channel verification parameter. If JV=1, a router 
will verify the coordinator is on its operating channel when joining or coming up from a 
power cycle. If a coordinator is not detected, the router will leave its current channel and 
attempt to join a new PAN. If JV=0, the router will continue operating on its current 
channel even if a coordinator is not detected.
R
0 - Channel verification 
disabled
1 - Channel verification 
enabled
0
NW
Network Watchdog Timeout. Set/read the network watchdog timeout value. If NW is 
set > 0, the router will monitor communication from the coordinator (or data collector) 
and leave the network if it cannot communicate with the coordinator for 3 NW periods. 
The timer is reset each time data is received from or sent to a coordinator, or if a many-
to-one broadcast is received.
R
0 - 0x64FF 
[x 1 minute]
(up to over 17 days)
0 (disabled)
JN
Join Notification. Set / read the join notification setting. If enabled, the module will 
transmit a broadcast node identification packet on power up and when joining. This 
action blinks the Associate LED rapidly on all devices that receive the transmission, and 
sends an API frame out the UART of API devices. This feature should be disabled for 
large networks to prevent excessive broadcasts.
RE
0 - 1
0
AR
Aggregate Routing Notification. Set/read time between consecutive aggregate route 
broadcast messages. If used, AR may be set on only one device to enable many-to-one 
routing to the device. Setting AR to 0 only sends one broadcast. AR is in units of 10 
seconds.
CR
0 - 0xFF
0xFF
Networking Commands
AT
Command
Name and Description
Node 
Type
1
Parameter Range
Default