E Series Data Radio – User Manual
 © Copyright 2005 Trio DataCom Pty. Ltd.
EH450 Quick Start Guide
Introduction
Welcome to the Quick Start Guide for the EH450 Hot Standby 
Base / Repeater Station. This section provides additional step-by-
step instructions to install, commission and operate the EH450 
Hot Standby Base Station. This document should be read in 
conjunction with the EB450 Base Station Quick Start Guide.
The EH450 is a fully redundant, hot standby digital data radio base 
/ repeater station providing automatic changeover facilities. 
The EH450 is designed as a modular solution, comprising 2 
identical EB450 base station units (standard) linked to a central, 
fail-safe monitoring and changeover controller (Hot Standby 
Controller). Either base station may be taken out for maintenance 
without the need for any system down time. The automatic 
changeover is triggered by out of tolerance (alarm) conditions 
based on either RF and/or user data throughput parameters.
Part E –  Getting Started - EH450
Features and Benefits
• 
Individual and identical base stations with separate control 
logic changeover panel
• 
Modules are hot swapable without user downtime
• 
Flexible antenna options – single, separate Tx & Rx, two Tx 
and two Rx
• 
Both on-line and off-line units monitored regardless of active 
status
• 
Also refer to the common Features and Benefits list of the E 
Series Data Radio
Base / Repeater Unit
Hot Standby Controller Unit
Base / Repeater Unit
Note: RF connectors not used on ETSI version
Rear View