1. New config 
 
Clicking on new config adds another row or another step to the entire algorithm.  
 
Each parameter group is composed of power, Q value, selection of transmit antenna, selection of receive 
antenna, and tag backscatter rate.  Each of these parameter groups will be run sequentially upon the 
command to find tags.  
 
Power level: The power level specifies the power given to tags during that particular loop. The power level 
is selectable between 0 and 30, correspondingly to the reader output power in dBm.   
 
Estimated tags: 
This field requires a mandatory input. It is an estimate of number of tags in the range of 
the reader. The value in this field enables the software to calculate a Q value. Default value for estimated 
tags is 10. 
 
Q value:
 The Q value sets the number of timeslots in which tags may respond to the reader.  The number 
of slots is 2
, and must be larger than the total number of tags.  Q is constrained to lie between 0 and 15. 
 
Refresh:  Enter a refresh time between 1 and 10 seconds to set the time period before the tag inventory 
process is repeated. 
 
The custom screen also allows the user to try out the new settings by clicking on Find Tags prior to saving 
the new settings.  
 