Koden Electronics Co. Ltd RB718A Manual Do Utilizador

Página de 13
 
81
CHAPTER 6.  MAINTENANCE AND INSPECTION 
 
A qualified engineer should carry out most of maintenance work on this radar. If your radar set has 
any problem, contact your local dealer for repair. 
 
 
Very High Voltage is present inside the radar set. Do 
not attempt to open the display rear cover or dis-
assemble internal module. When you open the ra-
dome, make sure to turn off the main power supply 
at switch board. 
Even if the radar is switched OFF, the radar set is 
still powered with very small amount of current. 
 
The following table shows the maintenance by user. Please check each item periodically. 
 
 
Tab. 6-1 Maintenance
 
 
 
Articles of consumption 
The radar uses the life-limited parts as listed below that require periodic replacement. 
 
(1) Magnetron 
This part is used in the scanner unit. If distant echo images have become weak, the 
magnetron probably may have degraded. In such a case, you need to replace this item. 
Consult your local service agent for replacement. 
Practical life to replacement: 3000hour(typ.) (500hour guaranteed by the magnetron 
manufacturer) 
 
(2) LCD back-light 
This part used in the display unit. If the display screen is extremely dark and its illumi-
nation cannot be corrected by adjusting the screen brightness, the LCD backlighting lamp 
may be faulty or may have burnt out. In such a case, you need to replace it. Consult your 
local agent for replacement. 
Period of the replacement: 15000 hours (typ.) (1000 hours at 0
°
C
Inspection Interval 
Inspection Item 
Method of Inspection and Maintenance 
3-6 months 
Rust and looseness in 
scanner unit 
Check if the scanner’s fitting bolts are corroded. 
 
Display screen of LCD 
display 
Clean the filter plate and LCD screen surfaces with a soft 
and wet cloth. Avoid organic solvent. 
6-12 months 
Grease application to 
antenna drive gear 
Apply an even coating of grease* to the entire surface of 
the antenna drive gear with a spatula or brush. 
 
Check for contact of 
connectors 
Check whether connectors are properly connected. If not, 
redo connection or make good contact by using a contact 
restoring chemical agent or by polishing or replace with a 
new one if necessary. 
 
Antenna motor 
 brush(RA52/53/54) 
Check the length of brushes.  If the length is less than 
6mm, replace both brushes with new one. 
WARNING