Inovonics Wireless Corporation 3B63MB4 Manual Do Utilizador

Página de 29
11 
Installation 
Notes:  Both base stations must be set to the same channel number and different lane numbers. 
 
Base station models C921 and earlier must be mounted at least 25 feet apart.  Base station models C922 
may be mounted as close as 2 feet apart.  Test the system prior to installation by placing the base 
stations in the desired locations.  Set Jumpers and program the headsets.  Insure that the talk L.E.D. on 
the proper base station lights when the appropriate (T1 and T2) button on the headset is pressed. 
Wiring the System  
 
Figure 11.  Cross-Lane Wiring Diagram 
Programming the Headsets for Cross-Lane Operation 
Follow the steps below to program the headsets for Cross-Lane operation, and disable the Talk-Lock function.  
It does not matter which base station is used to program the headsets.  By pressing T1, the headset will always 
communicate with the lane 1 base station; by pressing T2, the headset will always communicate with the lane 2 
base station. 
1.  Disable the Talk Lock function 
Talk-Lock is a toggle function that must be checked first to see if it is enabled or disabled.  If the Talk LED 
lights when the L button is pressed, Talk-Lock is enabled. 
•  To disable Talk-Lock, turn the headset OFF, press and hold the L button while pressing ON for 5 
seconds.  You will hear an acknowledging beep.