Section 1  TRACER Description
5
Preliminary
DS1/DSX-1 Interface
Two DS1/DSX-1 interfaces, labelled “T1A” and “T1B,” are provided for connecting to the T1
equipment.  Two types of physical interfaces are provided -- RJ-48C and bantam jacks.
The interfaces are illustrated in Figure 1-5, BBP Block Diagram.  The functions of the BBP are
partitioned into three printed circuit boards or PCBs, all contained in the same enclosure.
The DS1/DSX-1 interfaces provided for each channel are the same.  The upper bantam connectors,
labeled “Monitor,” provide isolated monitor points for testing.  The lower bantam jacks provide signal
insertion points.  The insertion of a bantam jack disconnects the RJ-48C connector from the circuit.  The
DS1/DSX-1 interface can operate on line lengths up to 6000 feet.
When connecting either T1 interface to the public switched network, an ADTRAN-provided cross-over
cable (part number 3125M011@A) is required to meet FCC part 68 and IC CS03 requirements.  This
cable is included with the BBP and is labelled “T1 Crossover.” This cable is required to cross-over the
TX and RX pairs to meet the connecting arrangement of a network interface device.
For connections to other CPE-type equipment, such as an ADTRAN TSU-100, a straight-through T1
cable is provided by ADTRAN (part number 3127004) and is included with the BBP.
Figure 1-5. BBP Block Diagram
Σ
T1
T1
T1C
Multiplex
Viterbi
Encoder/
Decoder
Spread
Spectrum
Data
Pump
90
90
Baseband Processor Board
IF  Interface  Board
Fc = 70 MHz
Fc = 140 MHz
Filter
µC
UART
DSP
-48Vdc
RS-232
T1A
T1B
I F
Figure 1-4. BBP Rear Panel
MANAGEMENT