For the T1 receiver to operate correctly, a minimum number of
“1s” must exist on the T1 facility.  If the data cannot be guaranteed
to meet this requirement, then another line coding format is used.
In the bipolar 8 zero substitution (B8ZS) scheme, a string of eight
“0s” is replaced by a special sequence of eight bits that contains a
bipolar violation.  The receiver, upon recognizing this sequence,
reinserts the eight “0s” and the data is recovered intact.
DS1/DSX-1 I
NTERFACE
When connecting the interface to the public switched network,
an ADTRAN-provided cross-over cable (part number
3125.M011@A) is required to meet FCC part 68 and IC CS03
requirements.  This cable is required to cross-over the Tx and Rx
pairs to meet the connecting arrangement of a network interface
device.  This cable is included with the BBP and is labelled “T1
Crossover.”
L
INE
 B
UILDOUT
 
OR
 LBO
The DS1/DSX-1 interface provides two different types of line
buildouts (LBOs), respectively.  When set for DS1, LBOs for 0␣ dB,
-7.5 dB, -15 dB, and -22 dB are available.  The DS1 interface can
operate on line lengths up to 6,000 feet.  When set for DSX-1
interface, LBOs for 0-133 feet, 266-399 feet, 399-533 feet, and
533-655 feet are available.