Adtran TRC4106 Manual Do Utilizador

Página de 68
Section 4, Network Turnup Procedure
TRACER 4206 System Manual
34
© 2002 ADTRAN, Inc.
612804206L1-1B
1.
INTRODUCTION
This section discusses the installation process of the TRACER 4106/4206 system.
2.
TOOLS REQUIRED
The tools required for the installation of the TRACER 4106/4206 are:
VT100 terminal or PC with terminal emulation software
RS-232 (DB-25 male for TRACER 4106/4206 end) cable for connecting to terminal
3.
UNPACK AND INSPECT THE SYSTEM
Each TRACER 4106/4206 is shipped in its own cardboard shipping carton. Open each carton carefully and 
avoid deep penetration into the carton with sharp objects. 
After unpacking the unit, inspect it for possible shipping damage. If the equipment has been damaged in 
transit, immediately file a claim with the carrier, then contact ADTRAN Customer Service (see Customer 
Service, Product Support Information, and Training
 information in the front of this manual).
Contents of ADTRAN Shipment
Your ADTRAN shipment includes the following items:
TRACER 4102 or TRACER 4206 unit
TRACER 4106/4206 Documentation CD
4 T1 Interconnect Cables (RJ-48C Straight-Through)
Customer Provides
The following items are necessary for the installation of the TRACER 4106/4206 system and are not 
provided by ADTRAN:
21 to 60 VDC power source (or AC adapter available from ADTRAN P/N 1280650L1), either polarity 
referenced to ground
Antenna and mounting hardware
Antenna feedline cable
Changes or modifications not expressly approved by ADTRAN could void the user’s 
authority to operate the equipment.
To prevent electrical shock, do not install equipment in a wet location or during a lightning 
storm.