Adtran TRC4106 Manual Do Utilizador

Página de 68
Section 5, User Interface Guide
TRACER 4206 System Manual
56
© 2002 ADTRAN, Inc.
612804206L1-1B
Figure 16.  T1C Status/Configuration/Loopback
>T1C S
TATUS
/C
ONFIGURATION
/L
OOPBACK
 > T1C I
NTERFACE
 A
LARMS
Displays and active alarms on the T1C link reported from both the local and remote TRACER 4106/4206 
units. These alarms include Red, Blue, Yellow, AIS, and bipolar violations (BPV). See Table 1 on page 
50, fo
r more information on these alarms.
>T1C S
TATUS
/C
ONFIGURATION
/L
OOPBACK
 > T1C L
INE
 B
UILD
 O
UT
Configures the T1C for the appropriate line buildout, based on the distance to the T1C equipment. 
>T1C S
TATUS
/C
ONFIGURATION
/L
OOPBACK
 > A
LARM
 R
EPORTING
Determines whether the TRACER 4106/4206 unit will report active alarms.  If 
D
ISABLED
, no alarms will 
be displayed on this menu page.  The Alarm Reporting parameter is independently configured for local and 
remote TRACER 4106/4206 units. When 
D
ISABLED
, the front panel LED alarms will also be disabled (off).
>T1C S
TATUS
/C
ONFIGURATION
/L
OOPBACK
 > S
IGNALING
Configure the framing format for the T1C link for both the local and remote TRACER 4106/4206 units.  
The TRACER 4106/4206 transports T1C data across the link (as long as the T1C signal is properly timed).  
Configure the framing format (using the 
S
IGNALING
 menu) to enable the TRACER 4106/4206 to monitor 
the incoming framing error events and indicate problems with the attached metallic service. The TRACER 
4106/4206 supports both 
ESF
 and 
D4
 framing formats.
Press <5> from any menu in the TRACER 4106/4206 VT100 menu structure to access the 
T1C Status/Configuration/Loopback menu page.