Adtran TRC4106L2 Manual Do Utilizador

Página de 60
TRACER 4106/4206 System Manual
Section 5  User Interface Guide
612804206L2-1A
© 2004 ADTRAN, Inc.
49
Both ends of the TRACER link must be set to the same number of active T1 ports. The TRACER 4106/4206 
comes factory programmed with 
A
CTIVE
 T1 P
ORTS
 set to 
4
X
T1
.
>TRACER S
YSTEM
 O
PTIONS
 > M
ODEM
 C
ONTROL
Configures the modem control leads on the RS-232 port (terminal interface located on the rear panel of the 
unit). Set 
M
ODEM
 C
ONTROL
 to 
E
NABLED
 when connecting the unit to a modem (using a null modem adapter). 
Setting 
M
ODEM
 C
ONTROL
 to 
D
ISABLED
 prevents the TRACER 4106/4206 from monitoring DCD and enables 
data to be sent to the VT100 continuously. 
M
ODEM
 C
ONTROL
 must be set to 
D
ISABLED
 when the VT100 
terminal is in use. The TRACER 4106/4206 comes factory programmed with 
M
ODEM
 C
ONTROL
 set to 
D
ISABLED
.
>TRACER S
YSTEM
 O
PTIONS
 > M
ODEM
 C
ONNECTION
 (L
OGOUT
)
Causes the TRACER 4106/4206 to de-assert Clear To Send (CTS) and DSR for a time greater than 20 msec. 
This signals the modem to disconnect the analog connection. Hangup-On-DTR-Drop may need to be 
explicitly enabled on some modems. If 
P
ASSWORD
 P
ROTECTION
 is 
E
NABLED
, this menu also causes the unit to 
close the current session and return to the TRACER System Status menu page and wait for password input.
>TRACER S
YSTEM
 O
PTIONS
 > P
ASSWORD
 E
NABLE
Configures password protection for the VT100 terminal interface. Password protection for the 
TRACER 4106/4206 requires password input from the TRACER 4106/4206 System Status menu page when 
connecting to the unit. When configured for password protection, the TRACER 4106/4206 closes any 
terminal session that remains inactive for more than 10 minutes. The TRACER 4106/4206 comes factory 
programmed with 
P
ASSWORD
 E
NABLE
 set to 
D
ISABLED
>TRACER S
YSTEM
 O
PTIONS
 > P
ASSWORD
Sets the password for password protection of the TRACER 4106/4206 VT100 terminal interface. Enter up to 
8 alphanumeric characters. The system password is case sensitive.
Table 1.  Receiver Sensitivity for the TRACER 4106/4206
Delivered 
Bandwidth
Receiver Sensitivity
Active
T1 Ports
TRACER 4106
TRACER 4206
4xT1
-93 dBm
-90 dBm
A – D
2xT1
-96 dBm
-93 dBm
A, B
1xT1
-98 dBm
-95 dBm
A
When changing active T1 ports on installed links, change the remote end first.  If the local 
end is changed first, remote configuration capability is lost.  In the event the local end is 
changed first and the link is dropped, reset the local end to the previous setting to restore 
the link.
Press <Ctrl+Z> three times from the terminal interface to disable 
M
ODEM
 C
ONTROL
 when 
the modem control leads are active.
The default password for the TRACER 4106/4206 is tracer.