Adtran TRC4108 Manual Do Utilizador

Página de 60
TRACER 4108/4208 System Manual
Section 5  User Interface Guide
612804208L1-1B
© 2003 ADTRAN, Inc.
49
>TRACER S
YSTEM
 O
PTIONS
 >A
CTIVE
 T1 P
ORTS
Configures the dynamic receive sensitivity functionality on the TRACER 4108/4208. When 
8
X
T1
 ports are 
active, the system receive sensitivity is -90 dBm (TRACER 4108) and -85 dBm (TRACER 4208). As the 
delivered bandwidth is decreased, receive sensitivity improves as follows:
Both ends of the TRACER link must be set to the same number of active T1 ports. The TRACER 4108/4208 
comes factory programmed with 
A
CTIVE
 T1 P
ORTS
 set to 
8
X
T1
.
>TRACER S
YSTEM
 O
PTIONS
 > M
ODEM
 C
ONTROL
Configures the modem control leads on the RS-232 port (terminal interface located on the rear panel of the 
unit). Set 
M
ODEM
 C
ONTROL
 to 
E
NABLED
 when connecting the unit to a modem (using a null modem adapter). 
Setting 
M
ODEM
 C
ONTROL
 to 
D
ISABLED
 prevents the TRACER 4108/4208 from monitoring DCD and enables 
data to be sent to the VT100 continuously. 
M
ODEM
 C
ONTROL
 must be set to 
D
ISABLED
 when the VT100 
terminal is in use. The TRACER 4108/4208 comes factory programmed with 
M
ODEM
 C
ONTROL
 set to 
D
ISABLED
.
>TRACER S
YSTEM
 O
PTIONS
 > M
ODEM
 C
ONNECTION
 (L
OGOUT
)
Causes the TRACER 4108/4208 to de-assert Clear To Send (CTS) and DSR for a time greater than 20 msec. 
This signals the modem to disconnect the analog connection. Hangup-On-DTR-Drop may need to be 
explicitly enabled on some modems. If 
P
ASSWORD
 P
ROTECTION
 is 
E
NABLED
, this menu also causes the unit to 
close the current session and return to the TRACER System Status menu page and wait for password input.
>TRACER S
YSTEM
 O
PTIONS
 > P
ASSWORD
 E
NABLE
Configures password protection for the VT100 terminal interface. Password protection for the 
TRACER 4108/4208 requires password input from the TRACER 4108/4208 System Status menu page when 
connecting to the unit. When configured for password protection, the TRACER 4108/4208 closes any 
terminal session that remains inactive for more than 10 minutes. The TRACER 4108/4208 comes factory 
programmed with 
P
ASSWORD
 E
NABLE
 set to 
D
ISABLED
>TRACER S
YSTEM
 O
PTIONS
 > P
ASSWORD
Sets the password for password protection of the TRACER 4108/4208 VT100 terminal interface. Enter up to 
8 alphanumeric characters. The system password is case sensitive.
Table 1.  Receiver Sensitivity for the TRACER 4108/4208
Delivered 
Bandwidth
Receiver Sensitivity
Active
T1 Ports
TRACER 4108
TRACER 4208
8xT1
-90 dBm
-85 dBm
A – H
4xT1
-93 dBm
-89 dBm
A – D
2xT1
-97 dBm
-92 dBm
A, B
Press <Ctrl+Z> three times from the terminal interface to disable 
M
ODEM
 C
ONTROL
 when 
the modem control leads are active.
The default password for the TRACER 4108/4208 is tracer.