Section 4, Network Turnup Procedure
TRACER 4305 System Manual
36
© 2002 ADTRAN, Inc.
612804305L1A-1A
ground that is in addition to the equipment grounding conductor in the power supply cord.
The supplementary equipment grounding conductor shall not be smaller in size than the ungrounded 
branch-circuit supply conductors. The supplementary equipment grounding conductor shall be connected 
to the product at the terminal provided, and shall be connected to ground in a manner that will retain the 
ground connection when the product is unplugged from the receptacle. The connection to ground of the 
supplementary equipment grounding conductor shall be in compliance with the rules for terminating 
bonding jumpers at Part K or Article 250 of the National Electrical Code, ANSI/NFPA 70. Termination of 
the supplementary equipment grounding conductor is permitted to be made to building steel, to a metal 
electrical raceway system, or to any grounded item that is permanently and reliably connected to the 
electrical service equipment ground.
The supplemental grounding conductor shall be connected to the equipment using a number 8 ring terminal 
and should be fastened to the grounding lug provided on the rear panel of the equipment. The ring terminal 
should be installed using the appropriate crimping tool (AMP P/N 59250 T-EAD Crimping Tool or 
equivalent.)
6.
SUPPLYING POWER TO THE UNIT
The TRACER 4305 can operate from a supply between 21 and 63 VDC, with either polarity referenced to 
ground. Power supplies should be able to provide up to 30 watts at the selected voltage. A dual pin 
terminal plug accepts power at the rear panel of the unit, providing a 
PWR
 pin and a 
GND
 point. Adapters 
for this plug are available for the ADTRAN +48V power supply (P/N 1175043L2).
7.
MOUNTING OPTIONS
Install the TRACER 4305 in a location that requires minimal antenna feedline length (the loss in this cable 
directly affects overall system performance). The TRACER 4305 is designed to be mounted in a rack. If 
multiple units are installed in one location, no space is needed between units, but certain regulations may 
require at least 0.75” of space above and below each unit.
8.
CONNECTING THE DS3 INTERFACE
The physical DS3 interface is provided using a pair of 75 
Ω
 BNC connectors for transmit and receive. 
Using standard coaxial cable, connect the 
DS3 OUT
 interface of the TRACER 4305 to the receive data 
interface of the DS3 equipment. Connect the 
DS3 IN
 interface of the TRACER 4305 to the transmit data 
interface of the DS3 equipment.
The supplemental equipment grounding terminal is located on the rear panel of the 
TRACER 4305.