Section 3  Operation
25
Preliminary
Char. / Point      Type
Scan Point Definition
Description
       1 / 1
     Status
Frequency Plan
0 = Plan A,
1 = Plan B
       1 / 2
     Status
10 Second BERT Test
0 = Normal,
1 = In Test
       1 / 3     Status
Local T1A Line Loopback
0 = Normal,
1 = Loop
       1 / 4
     Status
Local T1B Line Loopback
0 = Normal,
1 = Loop
       1 / 5
     Status
Local T1A Link Loopback
0 = Normal,
1 = Loop
       1 / 6
     Status
Local T1B Link Loopback
0 = Normal,
1 = Loop
       1 / 7
     Status
Remote T1A Link Loopback
0 = Normal,
1 = Loop
       1 / 8
     Status
Remote T1B Link Loopback
0 = Normal,
1 = Loop
       2 / 1
     Alarm
RFC Link Fail
0 = Normal,
1 = Alarm
       2 / 2
     Alarm
Code Sync Fail
0 = Normal,
1 = Alarm
       2 / 3     Alarm
Carrier Sync Fail
0 = Normal,
1 = Alarm
       2 / 4
     Alarm
T1 Mux Sync Fail (Link Err)
0 = Normal,
1 = Alarm
       2 / 5
     Alarm
Remote RF Link Down
0 = Normal,
1 = Alarm
       2 / 6
     Alarm
RF Low
0 = Normal,
1 = Alarm
       2 / 7
     Alarm
Remote Test Fail
0 = Normal,
1 = Alarm
       2 / 8
Unused
       3 / 1
     Alarm
T1A BPV
0 = Normal,
1 = Alarm
       3 / 2
     Alarm
T1A Red Alarm
0 = Normal,
1 = Alarm
       3 / 3
     Alarm
T1A Yellow Alarm
0 = Normal,
1 = Alarm
       3 / 4
     Alarm
T1A AIS (Blue Alarm)
0 = Normal,
1 = Alarm
       3 / 5
     Alarm
T1A Transmit AIS
0 = Normal,
1 = Alarm
       3 / 6
Unused
       3 / 7
Unused
       3 / 8
Unused
       4 / 1
     Alarm
T1B BPV
0 = Normal,
1 = Alarm
       4 / 2
     Alarm
T1B Red Alarm
0 = Normal,
1 = Alarm
       4 / 3     Alarm
T1B Yellow Alarm
0 = Normal,
1 = Alarm
       4 / 4
     Alarm
T1B AIS (Blue Alarm)
0 = Normal,
1 = Alarm
       4 / 5
     Alarm
T1B Transmit AIS
0 = Normal,
1 = Alarm
       4 / 6
Unused
       4 / 7
Unused
       4 / 8
Unused
Table 3-1.  TRACER TBOS Alarm and Status Map
A TBOS monitoring system will need to define the following bitmaps to indicate status and alarm