Adtran TRC6320 Manual Do Utilizador

Página de 128
612806320L1-1A
Copyright © 2005 ADTRAN, Inc.
 95
DLP-3
Setting IP Parameters for the TRACER System
Introduction
If the TRACER 6200 is connected to an IP network for Telnet, TFTP, or SNMP management, several IP 
parameters must be set for the unit to communicate with the network. These parameters are described in 
this DLP along with the procedures for setting them.
Prerequisite Procedures
This procedure assumes that the TRACER 6200 unit is connected to an IP network and is powered up.
Please see your Network Administrator for the proper assignment of the following 
parameters: 
IP 
ADDRESS
S
UBNET
 M
ASK
, and 
D
EFAULT
 G
ATEWAY
.
To prevent electrical shock, do not install equipment in a wet location or during a 
lightning storm.
Electronic equipment can be damaged by static electrical discharge. Before handling it, 
put on an antistatic discharge wrist strap to prevent damage to electronic components. 
Place equipment in antistatic packing material when transporting or storing. When 
working on equipment, always place it on an approved antistatic mat that is electrically 
grounded.