Adtran TRC6420L2X Manual Do Utilizador

Página de 132
Section 8  Troubleshooting Guide
TRACER 6000 Series Integrated System Manual
 132
Copyright © 2005 ADTRAN, Inc.
612806420L1-1E
11. Command a link loopback on the remote TRACER 64x0 unit and run a test pattern from the 
connected T1 equipment. This will verify the data path across the RF link. 
Installing/Configuring T1 Hardware
1. If possible, attach any or all of the intended T1 hardware to the TRACER 64x0 units using the 
same workbench setup. This step offers the perfect opportunity to configure your T1 hardware for 
proper functioning with the TRACER 64x0 hardware.
2. To significantly reduce the probability of an unsuccessful field installation, resolve any remaining 
T1 equipment-to-TRACER 64x0 configuration issues before field installation. See T1 Interface 
Alarms 
on page 127 
for more information on resolving T1 interface alarm conditions.
Installing/Configuring E1 Hardware
1. If possible, attach any or all of the intended E1 hardware to the TRACER 64x0 units using the 
same workbench setup. This step offers the perfect opportunity to configure your E1 hardware for 
proper functioning with the TRACER 64x0 hardware.
2. To significantly reduce the probability of an unsuccessful field installation, resolve any remaining 
E1 equipment-to-TRACER 64x0 configuration issues before field installation. See E1 Interface 
Alarms 
on page 128 
for more information on resolving E1 interface alarm conditions.
Installing/Configuring Ethernet Hardware
1. If possible, attach any or all of the intended Ethernet hardware to the TRACER 64x0 units using 
the same workbench setup. This step offers the perfect opportunity to configure your Ethernet 
hardware for proper functioning with the TRACER hardware.
2. To significantly reduce the probability of an unsuccessful field installation, resolve any remaining 
Ethernet equipment-to-TRACER 64x0 configuration issues before field installation.
Quad Ethernet Switch Module
 
Connect a computer (or Ethernet test equipment) to the TRACER 64x0 Ethernet interfaces. 
Perform a “ping” from one test station across the wireless link to another test station connected to 
the remote TRACER 64x0. This will verify the data path between the test equipment and the 
TRACER 64x0 unit.
4xE1 Module
 
Initiate a line loopback on the local TRACER 64x0 unit and run a test pattern from the connected 
E1 equipment. This will verify the connection between the E1 equipment and the local
 
TRACER 64x0 unit.
External pattern generators are required to test data path integrity. A T1/E1 BER tester is 
suggested.