Murata Electronics North America 2410P Manual Do Utilizador

Página de 59
WIT2410P 
© 2000- 2008 Cirronet™ Inc 
29 
M-2410P-0000 Rev G2 
5.4.  Status Commands  
 
These commands deal with general interface aspects of the operation of the WIT2410. 
 
 
Command 
 
Description 
 
zb[?|0|1]
 
 
 
Banner Display Disable 
 
0
 = disabled 
 
1
 = enabled   (default) 
 
zc[?|0..2]
 
 
 
Set Escape Sequence Mode 
 
0
 = disabled 
 
1
 = once after reset   (default) 
 
2 = unlimited times 
zh? 
Read factory serial number high byte. 
zm? 
Read factory serial number middle byte. 
zl? 
Read factory serial number low byte. 
zp[?|0-4] 
Set the duty cycle at which the modem will wake up to send and receive data.  
Duty cycle equals 1/2
N
 where the argument of the command equals N.
 
zq[?|0|1] 
 
(remote only) 
Low Power Acquisition Mode Enable 
 
0
 = Disabled (default) 
 
1
 = Enabled 
 
z>
 
 
Exit Modem Control Mode 
 
Banner Display Disable
  
Enables or disables display of the banner string and revision code automatically at power-
up.  May be disabled to avoid being mistaken for data by the host. 
 
Set Escape Sequence Mode
  
Enables or disables the ability to use the in-data-stream escape sequence method of 
accessing Control Mode by transmitting the string "
:wit2410
".  When this mode is set 
to 
1
, the escape sequence only works immediately after reset (this is the default).  When 
set to 
2
, the escape sequence may be used at any time in the data stream when preceded 
by a pause of 20 ms.  For backwards compatibility with the 
WIT2400
, the string 
"
:wit2400
" is also accepted for entering Control Mode.  Note that the escape sequence 
must be interpreted as data by the radio until the last character is received, and as such 
will be generally be transmitted to a receiving radio station, if any. 
 
Read Factory Serial Number High, Middle and Low Bytes. 
These read only commands return one of the three bytes of the unique factory-set serial 
number, which are also visible in the startup banner. 
 
Set Duty Cycle 
Allows reduced power consumption by having a remote wake up only every 2
N
 hops to 
receive and transmit.  Power consumption is roughly proportional to the duty cycle 
selected.  For example, if N=2, the remote will wake up every fourth hop.  Power