Murata Electronics North America 2492 Manual Do Utilizador

Página de 58
WIT2492 
 2000- 2007 Cirronet  
26
M-2492-0000 Rev G1 
 
 
 
Set Range Optimization (remote only) 
This command applies an adjustment factor to the over-the-air timing of remotes to 
compensate for the effects of propagation delay at long ranges.  The default setting of 
00H is suitable for ranges of 0 to 0.8 miles (1287 m), with optimal performance at 0.1 
miles (162m).  Each increment of this parameter adds 0.1 miles (162 m) to the working 
range. Thus the optimal and max ranges are determined by: 
 
optimal = 0.1mi + 0.1mi x dx = 0.17km + 0.17km x dx 
max = 0.8mi + 0.1mi x dx = 1.33km = 0.17km x dx 
 
The following table presents various values of dx and the associated optimal and max ranges. 
 
dx 
setting 
range: 
min 
 
optimal 
 
max 
00H 0mi/0km 
0.1mi/0.2km 
0.8mi/1.3km 
01H 0mi/0km 
0.2mi/0.3km 
0.9mi/1.5km 
04H 0mi/0km 
0.5mi/0.8km 
1.2 
mi/2.0km 
06H 0.1mi/0.2km 0.7mi/1.2km 1.4mi/2.3km 
09H 0.4mi/0.7km 1.0mi/1.6km 1.8 
mi/3.0km 
13H 1.4mi/2.3km 2.0mi/3.3km 2.8mi/4.7km 
31H 4.4mi/7.3km 5.0mi/8.3km 5.8 
mi/9.7km 
45H 6.4mi/10.7km 
7.0mi/11.7km 7.8mi/13.0km 
64H 9.4mi/15.7km 
10.0mi/16.7km 
10.8mi/18.0km 
C8H 19.3mi/32.3km 
20.0mi/33.3km 20.8mi/34.7km 
FAH 24.4mi/40.7km 
25.0mi/41.7km 25.8mi/43.0km 
Optimal 'dx' setting for various distances.