To change configuration parameters, the radio must be put into configuration mode by 
clicking on the Config Mode button on the WinCOM window immediately after opening 
WinCOM or after cycling power to the radio. Another method is to toggle the DTR by 
pressing the F1 key twice, which de-asserts then re-asserts DTR, then pressing the F3 key 
(or Config Mode button). 
 
 
 
When the radio is in configuration mode, a “>” prompt character is displayed in the 
WinCom window as shown above. Configuration parameters are sent to the radio by 
entering them in the WinCom window after the “>” prompt and pressing the Enter key. 
 
 
 
If an invalid command or value is entered, the radio will respond with “Error” as shown 
above Until the command to save the parameters (
m>
) is issued, the new parameters will 
only be valid until power is cycled or DTR is toggled by pressing the F1 key twice. 
 
New parameter values that have been issued are saved to non-volatile memory using the 
“m>” command. Refer to the Memory Commands section for details on this and other 
helpful memory commands. 
 
To exit configuration mode from the WinCom screen, use the “z>” command and press 
Enter as shown below. 
 
 
 
The return to the data mode is indicated by an absence of the “>” prompt. Refer to the 
Configuration Commands section below for details on all the configurable parameters. 
 
When the radio is linked to another radio, a communications test can be run by clicking 
on the Transmit button or pressing the F6 key. Whatever ASCII string is in the Transmit 
String window will be transmitted as shown below.