Murata Electronics North America 5811M Manual Do Utilizador

Página de 40
 
© 2003 Cirronet
 Incorporated 
16 
M-5811-0008 Rev -
 
 
 
4.  MODEM INTERFACE 
 
Electrical connection to the WIT5811 is made through a 16-pin male header on the modem 
module.  The signals are 3.3 volt signals and form an RS-232 style asynchronous serial 
interface.  The table below provides the connector pinout. 
 
Pin Signal Type Description 
GND 
Signal and chassis ground 
TXD 
Input 
Transmit data.  Input for serial data to be transmitted.  In Control 
Mode also used to transmit modem commands to the modem. 
RXD 
Output  Receive data.  Output for received serial data.  In Control Mode, 
also carries receive modem status from the modem. 
 
Input 
Configuration selector.  Used to switch between Control and Data 
Modes.  Normally, CFG will be set for Data Mode.  An internal 10K 
pull-up enables Data Mode if this signal is left unconnected.  
Control Mode is also accessible by transmitting an escape 
sequence immediately after wake up or power up. 
 
(0v) 
1 = Control Mode 
 
(3.3v)  0 = Data Mode 
 
Input 
Request to send.  Gates the flow of receive data from the radio to 
the user on or off.  In normal operation this signal should be 
asserted.  When negated, the WIT5811 buffers receive data until 
RTS is asserted. 
 
(0v) 
1 = Receive data (RxD) enabled 
 
(3.3v)  0 = Receive data (RxD) disabled. 
SLEEP 
Input 
Sleeps/wakes radio transceiver.  In sleep mode all radio functions 
are disabled consuming less than 50µA.  At wake up, any user 
programmed configuration settings are refreshed from non-volatile 
memory, clearing any temporary settings that may have been set. 
 
(3.3v)  1 = Sleep Radio 
 
(0v) 
0 = Wake Radio  
 
Output  Data carrier detect.  For remotes, indicates the remote has 
successfully acquired the hopping pattern of the base station. 
 
(0v) 
1 = Carrier detected (synchronized) 
 
(3.3v)  0 = No carrier detected (not synchronized) 
 
Output  Clear to send.  Used to control transmit flow from the user to the 
radio. 
 
(0v) 
1 = Transmit buffer not full, continue transmitting 
 
(3.3v)  0 = Transmit buffer full, stop transmitting 
 9 
Reserved for future use. Do not connect. 
10  Input 
Resets 
the 
radio. 
11-15 
Reserved for future use. Do not connect. 
16 
VCC 
Positive supply.  Min 3.3 v, 5.0 v nominal, 10.0 v max. 
RTS 
DCD 
CTS 
CFG 
Reset