Murata Electronics North America 910M Manual Do Utilizador

Página de 47
WIT910 
7.2.  Serial Connector Pinouts 
 
 
 
 
 
Signal 
 
WIT910  
OEM Pinout 
HN-591  
DB9 
Pinout 
GND 1 
TXD 2  3 
RXD 3 
CFG 4 
RTS 5  7 
SLEEP 6 
DCD 7 
CTS 8  8 
 
The HN-591 is wired as a DCE device and as such can be connected to DTE devices such 
as PCs with a straight-through cable.  When connecting a HN-591 to a DTE device, a 
“null modem” cable is required.  To effect a null modem cable, cross-wire TXD and 
RXD and connect ground.  The HN-591 can operate with just these three wires 
connected.  However, as the WIT910 does not support software flow control, there will 
be no flow control in this mode.  If the DTE device fails to respond, connect DCD from 
the HN-591 to the DTR and RTS inputs to activate the DCE device whenever the 
WIT910 asserts carrier.   
 
When connecting to the WIT910, make sure that all of the inputs (TXD, CFG, RTS and 
SLEEP) are terminated for proper operation. 
 
 
7.3.  Approved Antennas 
 
The WIT910 is designed to ensure that no antenna other than the one fitted shall be used 
with the device.  The end user must permanently affix the antenna by using an adhesive 
on the coupling such as Loctite, or ensure the antenna has a unique coupling. The table 
below lists the antennas which can be purchased directly from Cirronet.  Contact Cirronet 
Technical Support with any questions. 
 
Description Gain 
Part 
Number 
Coupling 
9dB Yagi Directional 
9dB 
YAGI099 
Male Rev TNC 
6dB Yagi Directional 
6dB 
YAGI096 
Male Rev TNC 
5dB Omnidirectional 
5dB 
OMNI095 
Male Rev TNC 
2dB Omnidirectional 
2dB 
OMNI092 
Male Rev TNC 
 
 
© 2000- 2004 Cirronet Inc 
38 
M-0910-0000 Rev -