Murata Electronics North America DNT24 Manual Do Utilizador

Página de 83
www.Murata.com
Technical support +1.678.684.2000
Page 38 of 83
© 2015 by Murata Manufacturing Co. Ltd.
E-mail:
tech_sup@murata.com
DNT24 Integration Guide – 03/04/15
SetRemoteRegister command and reply format details are shown in Tables 7.3.15 and 7.3.16:
Set Remote Register Command
Byte Offset
Field
Description
0x00
Start-of-Packet
0xFB = Indicates start of protocol formatted message
0x01
Length
Number of bytes in message following this byte
0x02
Packet Type
0x07 = SetRemoteRegister
0x03 - 0x05
Destination MAC Address
Destination MAC address, in Little Endian byte order
0x06
Register Offset
Register offset in its bank
0x07
Register Bank
Register bank number
0x08
Register Size
Register size in bytes
0x09 - 0x18
Register Value
Register contents
Table 7.3.15
Set Remote Register Reply
Byte Offset
Field
Description
0x00
Start-of-Packet
0xFB = Indicates start of protocol formatted message
0x01
Length
0x06 = Number of bytes in message following this byte
0x02
Packet Type
0x17 = SetRemoteRegisterReply
0x03
Status
Error status: 0x00 = no error, 0xE1 = invalid argument
0x04 - 0x06
Originator MAC Address
Originator’s MAC address, in Little Endian byte order
0x07
RSSI
Packet RX power in dBm, -128 to 126, or 127 if invalid
Table 7.3.16
RxData event packet format details are shown in Figure Table 7.3.17:
RX Data Packet
Byte Offset
Field
Description
0x00
Start-of-Packet
0xFB = Indicates start of protocol formatted message
0x01
Length
0x00 to 0x6D = Number of bytes in message following this byte
0x02
Packet Type
0x26 = RxData event message
0x03 - 0x05
Originator MAC Address
Originator’s MAC address, in Little Endian byte order
0x06
RSSI
Packet RX power in dBm, -128 to 126, or 127 if invalid
0x07 - 0x73
Rx Data
Up to 105 bytes of data from Base, up to 109 bytes from Router or Remote
Table 7.3.17